Joints are formed in concrete slabs as part of the process of constructing rigid paving for roads. Joints are discontinuities in the pavement slab that are necessary to allow for expansion, contraction and warping. Rigid paving consists of a reinforced or unreinforced insitu concrete slab laid over a thin granular base course. The rigidity and strength of the pavement enables the loads and stresses to be distributed over a wide area of the subgrade.
Joints are spaced depending on a range of factors:
- The amount of reinforcement used.
- The proposed traffic intensity.
- The slab thickness.
- The frictional restraint of the subgrade.
- The temperature at which the concrete is laid.
Joints comprise a filler which separates the slabs, and a sealing compound which is used to fill the top 25 mm of the joint to prevent the entry of water and grit. Suitable jointing materials include impregnated fibre board, cork, sheet bitumen, and rubber. The joint sealing compound must have good adhesion to concrete, extensibility without fracture, resistance to flow in hot weather, and durability.
A system of dowel bars in introduced between slabs to prevent slab movement and ensure load-transfer. Dowel bars are positioned at mid-depth of the slab at centres of 300 mm. The diameter of the bar usually ranges from 20-30 mm but varies with the slab thickness. A plastic sleeve 100 mm-long is inserted on one end of the dowel to allow free movement of the slab. The sleeve should contain a pad of compressible material at the end.
[edit] Types of road joints
There are a number of different types of joints:
[edit] Expansion joint
These are provided along the transverse direction to allow the expansion and contraction of a concrete slab due to temperature and subgrade moisture variation. They are intended to prevent potentially damaging forces accumulating within the slab itself or surrounding structures. Maximum spacing of expansion joints range from 25-27 m in jointed reinforced concrete slabs, and from 40 m (for slabs <230 mm thick) to 60 m (for slabs >230 mm thick) in unreinforced concrete.
[edit] Contraction joint
These are also known as ‘shrinkage’ joints and are provided along the transverse direction to allow for contraction or shrinkage of the slab during the curing process. Maximum spacing of contraction joints ranges from 12-24 m in reinforced slabs, and from 4-5 m in unreinforced slabs.
[edit] Construction joint
Construction joints are provided whenever the construction work stops temporarily. They can be either along the transverse or longitudinal direction.
[edit] Warping joint
Warping joints are provided along the longitudinal direction to prevent warping of the concrete slab due to temperature and subgrade moisture variation.
[edit] Related articles on Designing Buildings
- Bituminous mixing and laying plant.
- Code of Practice for Ironwork Systems Installation and Refurbishment.
- Highway drainage.
- Joint v connection.
- Kerbs.
- Overview of the road development process.
- Pavement.
- Road construction.
- Runway construction.
- Settlement.
- Types of road and street.
[edit] External references
- ‘Introduction to civil engineering construction’ (3rd ed.), HOLMES, R., The College of Estate Management (1995)
Featured articles and news
Shortage of high-quality data threatening the AI boom
And other fundamental issues highlighted by the Open Data Institute.
Data centres top the list of growth opportunities
In robust, yet heterogenous world BACS market.
Increased funding for BSR announced
Within plans for next generation of new towns.
New Towns Taskforce interim policy statement
With initial reactions to the 6 month policy update.
Heritage, industry and slavery
Interpretation must tell the story accurately.
PM announces Building safety and fire move to MHCLG
Following recommendations of the Grenfell Inquiry report.
Conserving the ruins of a great Elizabethan country house.
BSRIA European air conditioning market update 2024
Highs, lows and discrepancy rates in the annual demand.
50 years celebrating the ECA Apprenticeship Awards
As SMEs say the 10 years of the Apprenticeship Levy has failed them.
Nominations sought for CIOB awards
Celebrating construction excellence in Ireland and Northern Ireland.
EPC consultation in context: NCM, SAP, SBEM and HEM
One week to respond to the consultation on reforms to the Energy Performance of Buildings framework.
CIAT Celebrates 60 years of Architectural Technology
Find out more #CIAT60 social media takeover.
The BPF urges Chancellor for additional BSR resources
To remove barriers and bottlenecks which delay projects.
Flexibility over requirements to boost apprentice numbers
English, maths and minimumun duration requirements reduced for a 10,000 gain.
A long term view on European heating markets
BSRIA HVAC 2032 Study.
Humidity resilience strategies for home design
Frequency of extreme humidity events is increasing.
National Apprenticeship Week 2025
Skills for life : 10-16 February